Description
9A & 16A Soft Starts
The ICM870 Soft Start is intended for residential, commercial, RV & marine applications. The ICM870 integrates compressor or motor in-rush current over startup time, thus reducing peak current demand on a power supply source by up to 70%.
Effectively reducing power draw to the A/C, the ICM870 utilizes a built-in self learning algorithm to deliver the optimal in-rush current per application. The ICM870 will monitor system health including voltage, current, compressor startup and integrity. Upon a fault condition, it will halt operation and initiate a 3 minute anti-short cycle routine while providing diagnostic fault information by means of an LED indicator.
*New feature: Upon installation and every start cycle, the ICM870 soft start will initiate a routine 4-minute start delay indicated by a rapid flashing Red LED indicator light. Power on the A/C unit and wait 4-minutes for the delay routine to conclude. This should follow with a successful call from the thermostat, A/C startup and the LED indicator light to change from Red to Green. This feature has been added as a benefit to protect the compressor and ICM870 from rapid short cycling during startup.
Related Article:
> Learn more about the benefits of a soft start in residential applications here.
> Recreational Vehicle Installation Guides, Per A/C Model
DETAILS:
Features & Benefits
- Reduces in-rush current/draw necessary at startup by up to 70%
- Prolong the life of the A/C by reducing excessive torque, wear and tear
- 4-minute on start delay
- Reduce loud noises, light flickering, and breaker trips
- Built-in self-learning algorithm
- Over-current protection
- Over/under voltage monitoring
- Built-in start capacitor
- LED fault indicators
- Ultrasonic sealed tamper-proof enclosure
- Installation hardware is included
Which Model Do I Need?
Refer to your service panel or user manual to determine your actual RLA rating.
ICM870-9A: For use with a Compressor Load Amp Rating (RLA) of up to Maximum of 9A
ICM870-16A: For use with a Compressor Load Amp Rating (RLA) of 9.1-16A Maximum
ICM870-32A: For use with a Compressor Load Amp Rating (RLA) of 16.1-32A Maximum
Air Conditioning & Heat Pump Loads Average (for reference only) | ||||
Size | BTU | *RLA | ICM870-model | |
1 Ton | 12,000 | 6 | ICM870-9A | |
2 Ton | 24,000 | 12 | ICM870-16A | |
3 Ton | 36,000 | 16 | ICM870-16A | |
4 Ton | 48,000 | 22 | ICM870-32A | |
5 Ton | 60,000 | 26 | ICM870-32A | |
6 Ton | 72,000 | 32 | ICM870-32A |
*This chart is intended as a quick reference only. It reflects the average Single-Phase Air Conditioning and Heat Pump conversions of Tonnage, BTUs, and RLA. Please refer to your service panel or user manual to determine your equipments actual RLA rating before deciding which model ICM870 you need.
SPECIFICATIONS:
Semi-Conductor Soft-Start Motor Controller, Form 2, Bypassed Controller
SCCR: 5kA Ue = 240 VAC
Ui = 240 VAC Uimp = 4kv
FCC Class B Pollution degree 3 UL File E340301
UL 60947-4-2 and IEC 60947-4-2
Input:
(L1, L2) 100-240 VAC 50/60Hz
Over voltage limits: 115 VAC nominal = 140 VAC, 240 VAC nominal = 264 VAC
Under voltage limits: 115 VAC nominal = 95 VAC, 240 VAC nominal =195 VAC
Outputs:
Compressor
Solid state/relay
Current: Max. nominal = 9 FLA for ICM870-9A,
16 FLA for ICM870-16A
Over current limits: ICM870-9A = 11.25A,
ICM870-16A = 20A
Environmental:
Ambient temperature: 40°C @ 16 FLA, 8 h duty 50°C @ 16 FLA, Temporary duty F = 30% (3 mins ON and 7 mins OFF), S = 6 (6 cycles per hour)
Storage temperature: -40°F to 149°F (-40°C to 65°C)
Humidity: 0-95% non-condensing
Enclosure: IP65
Dimensions: ICM870-9A/16A (7.60 x 3.20 x 2.10)
Screw Hole Center Points: 7.36 x 2.90
WEIGHT/DIMENSIONS:
7.63 x 3.19 x 2.13